Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 59.557
3.
Radiat Oncol ; 19(1): 54, 2024 May 03.
Article En | MEDLINE | ID: mdl-38702761

BACKGROUND: Stereotactic ablative body radiotherapy (SABR) is an emerging treatment alternative for patients with localized low and intermediate risk prostate cancer patients. As already explored by some authors in the context of conventional moderate hypofractionated radiotherapy, focal boost of the index lesion defined by magnetic resonance imaging (MRI) is associated with an improved biochemical outcome. The objective of this phase II trial is to determine the effectiveness (in terms of biochemical, morphological and functional control), the safety and impact on quality of life, of prostate SABR with MRI guided focal dose intensification in males with intermediate and high-risk localized prostate cancer. METHODS: Patients with intermediate and high-risk prostate cancer according to NCCN definition will be treated with SABR 36.25 Gy in 5 fractions to the whole prostate gland with MRI guided simultaneous integrated focal boost (SIB) to the index lesion (IL) up to 50 Gy in 5 fractions, using a protocol of bladder trigone and urethra sparing. Intra-fractional motion will be monitored with daily cone beam computed tomography (CBCT) and intra-fractional tracking with intraprostatic gold fiducials. Androgen deprivation therapy (ADT) will be allowed. The primary endpoint will be efficacy in terms of biochemical and local control assessed by Phoenix criteria and post-treatment MRI respectively. The secondary endpoints will encompass acute and late toxicity, quality of life (QoL) and progression-free survival. Finally, the subgroup of high-risk patients will be involved in a prospective study focused on immuno-phenotyping. DISCUSSION: To the best of our knowledge, this is the first trial to evaluate the impact of post-treatment MRI on local control among patients with intermediate and high-risk prostate cancer undergoing SABR and MRI guided focal intensification. The results of this trial will enhance our understanding of treatment focal intensification through the employment of the SABR technique within this specific patient subgroup, particularly among those with high-risk disease, and will help to clarify the significance of MRI in monitoring local responses. Hopefully will also help to design more personalized biomarker-based phase III trials in this specific context. Additionally, this trial is expected to be incorporated into a prospective radiomics study focused on localized prostate cancer treated with radiotherapy. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT05919524; Registered 17 July 2023. TRIAL SPONSOR: IRAD/SEOR (Instituto de Investigación de Oncología Radioterápica / Sociedad Española de Oncología Radioterápica). STUDY SETTING: Clinicaltrials.gov identifier: NCT05919524; Registered 17 July 2023. TRIAL STATUS: Protocol version number and date: v. 5/ 17 May-2023. Date of recruitment start: August 8, 2023. Date of recruitment completion: July 1, 2024.


Prostatic Neoplasms , Radiosurgery , Radiotherapy, Image-Guided , Humans , Male , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Radiosurgery/methods , Radiotherapy, Image-Guided/methods , Urinary Bladder/radiation effects , Organs at Risk/radiation effects , Organ Sparing Treatments/methods , Magnetic Resonance Imaging/methods , Prospective Studies , Quality of Life , Radiotherapy Dosage , Aged , Radiotherapy Planning, Computer-Assisted/methods , Middle Aged
4.
Opt Lett ; 49(9): 2425-2428, 2024 May 01.
Article En | MEDLINE | ID: mdl-38691735

Cherenkov imaging is an ideal tool for real-time in vivo verification of a radiation therapy dose. Given that radiation is pulsed from a medical linear accelerator (LINAC) together with weak Cherenkov emissions, time-gated high-sensitivity imaging is required for robust measurements. Instead of using an expensive camera system with limited efficiency of detection in each pixel, a single-pixel imaging (SPI) approach that maintains promising sensitivity over the entire spectral band could be used to provide a low-cost and viable alternative. A prototype SPI system was developed and demonstrated here in Cherenkov imaging of LINAC dose delivery to a water tank. Validation experiments were performed using four regular fields and an intensity-modulated radiotherapy (IMRT) delivery plan. The Cherenkov image-based projection percent depth dose curves (pPDDs) were compared to pPDDs simulated by the treatment planning system (TPS), with an overall average error of 0.48, 0.42, 0.65, and 1.08% for the 3, 5, 7, and 9 cm square beams, respectively. The composite image of the IMRT plan achieved a 85.9% pass rate using 3%/3 mm gamma index criteria, in comparing Cherenkov intensity and TPS dose. This study validates the feasibility of applying SPI to the Cherenkov imaging of radiotherapy dose for the first time to our knowledge.


Particle Accelerators , Time Factors , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage
5.
Biomed Phys Eng Express ; 10(4)2024 May 10.
Article En | MEDLINE | ID: mdl-38697044

Objective.The aim of this work was to develop a Phase I control chart framework for the recently proposed multivariate risk-adjusted Hotelling'sT2chart. Although this control chart alone can identify most patients receiving extreme organ-at-risk (OAR) dose, it is restricted by underlying distributional assumptions, making it sensitive to extreme observations in the sample, as is typically found in radiotherapy plan quality data such as dose-volume histogram (DVH) points. This can lead to slightly poor-quality plans that should have been identified as out-of-control (OC) to be signaled in-control (IC).Approach. We develop a robust iterative control chart framework to identify all OC patients with abnormally high OAR dose and improve them via re-optimization to achieve an IC sample prior to establishing the Phase I control chart, which can be used to monitor future treatment plans.Main Results. Eighty head-and-neck patients were used in this study. After the first iteration, P14, P67, and P68 were detected as OC for high brainstem dose, warranting re-optimization aimed to reduce brainstem dose without worsening other planning criteria. The DVH and control chart were updated after re-optimization. On the second iteration, P14, P67, and P68 were IC, but P40 was identified as OC. After re-optimizing P40's plan and updating the DVH and control chart, P40 was IC, but P14* (P14's re-optimized plan) and P62 were flagged as OC. P14* could not be re-optimized without worsening target coverage, so only P62 was re-optimized. Ultimately, a fully IC sample was achieved. Multiple iterations were needed to identify and improve all OC patients, and to establish a more robust control limit to monitor future treatment plans.Significance. The iterative procedure resulted in a fully IC sample of patients. With this sample, a more robust Phase I control chart that can monitor OAR doses of new plans was established.


Organs at Risk , Quality Control , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Head and Neck Neoplasms/radiotherapy , Algorithms
6.
Sci Rep ; 14(1): 10149, 2024 05 02.
Article En | MEDLINE | ID: mdl-38698048

This study aims to investigate the potential impact of high-dose radiotherapy (RT) on brain structure, cognitive impairment, and the psychological status of patients undergoing brain tumor treatment. We recruited and grouped 144 RT-treated patients with brain tumors into the Low dose group (N = 72) and the High dose group (N = 72) according to the RT dose applied. Patient data were collected by using the HADS and QLQ-BN20 system for subsequent analysis and comparison. Our analysis showed no significant correlation between the RT doses and the clinicopathological characteristics. We found that a high dose of RT could aggravate cognitive impairment and deteriorate patient role functioning, indicated by a higher MMSE and worsened role functioning in the High dose group. However, the depression status, social functioning, and global health status were comparable between the High dose group and the Low dose group at Month 0 and Month 1, while being worsened in the High dose group at Month 3, indicating the potential long-term deterioration of depression status in brain tumor patients induced by high-dose RT. By comparing patient data at Month 0, Month 1, Month 3, Month 6, and Month 9 after RT, we found that during RT treatment, RT at a high dose could aggravate cognitive impairment in the short term and lead to worsened patient role functioning, and even deteriorate the overall psychological health status of patients in the long term.


Brain Neoplasms , Cognitive Dysfunction , Humans , Male , Female , Cognitive Dysfunction/etiology , Brain Neoplasms/radiotherapy , Brain Neoplasms/psychology , Middle Aged , Aged , Brain/radiation effects , Brain/pathology , Adult , Radiotherapy Dosage , Depression/etiology , Quality of Life
7.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(4): 773-779, 2024 Apr 20.
Article Zh | MEDLINE | ID: mdl-38708512

OBJECTIVE: To investigate the dosimetric difference between manual and inverse optimization in 3-dimensional (3D) brachytherapy for gynecologic tumors. METHODS: This retrospective study was conducted among a total of 110 patients with gynecologic tumors undergoing intracavitary combined with interstitial brachytherapy or interstitial brachytherapy. Based on the original images, the brachytherapy plans were optimized for each patient using Gro, IPSA1, IPSA2 (with increased volumetric dose limits on the basis of IPSA1) and HIPO algorithms. The dose-volume histogram (DVH) parameters of the clinical target volume (CTV) including V200, V150, V100, D90, D98 and CI, and the dosimetric parameters D2cc, D1cc, and D0.1cc for the bladder, rectum, and sigmoid colon were compared among the 4 plans. RESULTS: Among the 4 plans, Gro optimization took the longest time, followed by HIPO, IPSA2 and IPSA1 optimization. The mean D90, D98, and V100 of HIPO plans were significantly higher than those of Gro and IPSA plans, and D90 and V100 of IPSA1, IPSA2 and HIPO plans were higher than those of Gro plans (P < 0.05), but the CI of the 4 plans were similar (P > 0.05). For the organs at risk (OARs), the HIPO plan had the lowest D2cc of the bladder and rectum; the bladder absorbed dose of Gro plans were significantly greater than those of IPSA1 and HIPO (P < 0.05). The D2cc and D1cc of the rectum in IPSA1, IPSA2 and HIPO plans were better than Gro (P < 0.05). The D2cc and D1cc of the sigmoid colon did not differ significantly among the 4 plans. CONCLUSION: Among the 4 algorithms, the HIPO algorithm can better improve dose coverage of the target and lower the radiation dose of the OARs, and is thus recommended for the initial plan optimization. Clinically, the combination of manual optimization can achieve more individualized dose distribution of the plan.


Algorithms , Brachytherapy , Genital Neoplasms, Female , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Brachytherapy/methods , Female , Retrospective Studies , Genital Neoplasms, Female/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiometry/methods
8.
J Coll Physicians Surg Pak ; 34(5): 573-577, 2024 May.
Article En | MEDLINE | ID: mdl-38720219

OBJECTIVE:  To compare the acute toxicities of two radiation treatment techniques, intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (3D-CRT) in localised prostate adenocarcinoma. STUDY DESIGN: Descriptive study. Place and Duration of the Study: Department of Oncology, Dr. Ziauddin Hospital, Karachi, Pakistan, from July 2016 to June 2022. METHODOLOGY: Patients with localised prostate adenocarcinoma who underwent treatment using two different advanced radiotherapy techniques i.e., IMRT and 3D-CRT were recruited during the study period. They were followed up for six months for acute gastrointestinal (GI) and genitourinary (GU) adverse events (acute toxicities) related to both treatment modalities according to Modified radiation therapy oncology group (RTOG) criteria. The acute toxicities were assessed at the 2nd, 4th, and 6th week during treatment and at the 3rd and 6th month after treatment. RESULTS:  There were 78 patients, with 39 patients in each group. The mean age was 68 ± 10 years in the 3D-CRT and 68 ± 07 years in the IMRT group. Patients in the IMRT group exhibited markedly lower treatment-related acute GI and GU effects at the end of 4th and 6th weeks for anorectal pain (p = 0.04) and (p = 0.01) and burning micturition (p = 0.003) and (p = 0.01), respectively. Furthermore, at 3 months anorectal pain (p = 0.02), loose stools (p = 0.005), and burning micturition (p = 0.01) were present and at 6 months anorectal pain was (p = 0.01) still present. CONCLUSION: Radiation therapy modalities 3D-CRT and IMRT both showed acceptable toxicity profile in the management of localised prostate cancer, while IMRT group exhibited significantly lower treatment-related acute GI and GU effects. KEY WORDS: 3D-CRT (3-Dimensional Conformal Radiation Therapy), IMRT (Intensity-Modulated Radiation Therapy), Radiation toxicity.


Prostatic Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Male , Prostatic Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Aged , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Middle Aged , Radiation Injuries/etiology , Adenocarcinoma/radiotherapy , Adenocarcinoma/pathology , Pakistan , Radiotherapy Dosage
9.
Sci Rep ; 14(1): 10637, 2024 05 09.
Article En | MEDLINE | ID: mdl-38724569

Hadron therapy is an advanced radiation modality for treating cancer, which currently uses protons and carbon ions. Hadrons allow for a highly conformal dose distribution to the tumour, minimising the detrimental side-effects due to radiation received by healthy tissues. Treatment with hadrons requires sub-millimetre spatial resolution and high dosimetric accuracy. This paper discusses the design, fabrication and performance tests of a detector based on Gas Electron Multipliers (GEM) coupled to a matrix of thin-film transistors (TFT), with an active area of 60 × 80 mm2 and 200 ppi resolution. The experimental results show that this novel detector is able to detect low-energy (40 kVp X-rays), high-energy (6 MeV) photons used in conventional radiation therapy and protons and carbon ions of clinical energies used in hadron therapy. The GEM-TFT is a compact, fully scalable, radiation-hard detector that measures secondary electrons produced by the GEMs with sub-millimetre spatial resolution and a linear response for proton currents from 18 pA to 0.7 nA. Correcting known detector defects may aid in future studies on dose uniformity, LET dependence, and different gas mixture evaluation, improving the accuracy of QA in radiotherapy.


Radiometry , Radiometry/instrumentation , Radiometry/methods , Humans , Radiotherapy/methods , Radiotherapy/standards , Radiotherapy/instrumentation , Quality Assurance, Health Care , Electrons , Radiotherapy Dosage , Neoplasms/radiotherapy , Equipment Design , Proton Therapy/instrumentation , Proton Therapy/methods
10.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 156-159, 2024 Mar 30.
Article Zh | MEDLINE | ID: mdl-38605614

Objective: The distribution of the photon energy spectrum in isocenter plane of the medical linear accelerator and the influence of secondary collimator on the photon energy spectrum are studied. Methods Use the BEAMnrc program to simulate the transmission of the 6 MeV electrons and photons in 5 cm×5 cm,10 cm×10 cm,15 cm×15 cm and 20 cm×20 cm fields in treatment head of the medical linear accelerator, where a phase space file was set up at the isocenter plane to record the particle information passing through this plane. The BEAMdp program is used to analyze the phase space file, in order to obtain the distribution of the photon energy spectrum in isocenter plane and the influence of secondary collimator on the photon energy spectrum. Results: By analyzing the photon energy spectrum of a medical linear accelerator with a nominal energy of 6 MV, it is found that the secondary collimator has little effect on the photon energy spectrum; different fields have different photon energy spectrum distributions; the photon energy spectrum in different central regions of the same field have the same normalized distribution. Conclusion: In the dose calculation of radiation therapy, the influence of photon energy spectrum should be carefully considered.


Photons , Radiotherapy Planning, Computer-Assisted , Monte Carlo Method , Photons/therapeutic use , Particle Accelerators , Phantoms, Imaging , Radiotherapy Dosage
11.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 150-155, 2024 Mar 30.
Article Zh | MEDLINE | ID: mdl-38605613

Objective: A quality control (QC) system based on the electronic portal imaging device (EPID) system was used to realize the Multi-Leaf Collimator (MLC) position verification and dose verification functions on Primus and VenusX accelerators. Methods: The MLC positions were calculated by the maximum gradient method of gray values to evaluate the deviation. The dose of images acquired by EPID were reconstructed using the algorithm combining dose calibration and dose calculation. The dose data obtained by EPID and two-dimensional matrix (MapCheck/PTW) were compared with the dose calculated by Pinnacle/TiGRT TPS for γ passing rate analysis. Results: The position error of VenusX MLC was less than 1 mm. The position error of Primus MLC was significantly reduced after being recalibrated under the instructions of EPID. For the dose reconstructed by EPID, the average γ passing rates of Primus were 98.86% and 91.39% under the criteria of 3%/3 mm, 10% threshold and 2%/2 mm, 10% threshold, respectively. The average γ passing rates of VenusX were 98.49% and 91.11%, respectively. Conclusion: The EPID-based accelerator quality control system can improve the efficiency of accelerator quality control and reduce the workload of physicists.


Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Algorithms , Calibration , Electronics , Radiotherapy, Intensity-Modulated/methods , Radiometry/methods
12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 184-191, 2024 Mar 30.
Article Zh | MEDLINE | ID: mdl-38605619

More than 70% of tumor patients require radiotherapy. Medical electron linear accelerators are important high-end radiotherapy equipment for tumor radiotherapy. With the application of artificial intelligence technology in medical electron linear accelerator, radiotherapy has evolved from ordinary radiotherapy to today's intelligent radiotherapy. This study introduces the development history, working principles and system composition of medical electron linear accelerators. It outlines the key technologies for improving the performance of medical linear electron accelerators, including beam control, multi-leaf collimator, guiding technology and dose evaluation. It also looks forward to the development trend of major radiotherapy technologies, such as biological guided radiotherapy, FLASH radiotherapy and intelligent radiotherapy, which provides references for the development of medical electron linear accelerators.


Electrons , Neoplasms , Humans , Artificial Intelligence , Particle Accelerators , Radiotherapy Dosage
13.
Lab Chip ; 24(8): 2335-2346, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38568477

We describe the first microfluidic device for in vitro testing of brachytherapy (BT), with applications in translational cancer research. Our PDMS-made BT-on-chip system allows highly precise manual insertion of clinical BT seeds, reliable dose calculation using standard clinically-used TG-43 formalism and easy culture of naturally hypoxic spheroids in less than 3 days, thereby increasing the translational potential of the device. As the BT-on-chip platform is designed to be versatile, we showcase three different gold-standard post-irradiation bioassays and recapitulate, for the first time on-chip, key clinical observations such as dose rate effect and hypoxia-induced radioresistance. Our results suggest that BT-on-chip can be used to safely and efficiently integrate BT and radiotherapy to translational research and drug development pipelines, without expensive equipment or complex workflows.


Brachytherapy , Brachytherapy/methods , Radiotherapy Dosage , Biology
15.
PLoS One ; 19(4): e0301435, 2024.
Article En | MEDLINE | ID: mdl-38635642

In radiotherapy, when photon energy exceeding 8 MV is utilized, photoneutrons can activate the components within the gantry of the linear accelerator (linac). At the end of the linac's lifecycle, radiation workers are tasked with its dismantling and disposal, potentially exposing them to unintentional radiation. This study aims to identify and measure the radioisotopes generated by this activation through spectroscopy, and to evaluate the effective dose rate. We selected nine medical linacs, considering various factors such as manufacturer (Siemens, Varian, and Elekta), model, energy, period of operation, and workload. We identified the radionuclides in the linac head by employing an in situ high-purity germanium (HPGe) detector. Spectroscopy and dose-rate measurements were conducted post-shutdown. We also measured the dose rates at the beam-exit window following irradiation with 10 MV and 15 MV photon beams. As a result of the spectroscopy, we identified approximately 20 nuclides including those with half-lives of 100 days or longer, such as 54Mn, 60Co, 65Zn, 122Sb, and 198Au. The dose rate measurements after 10 MV irradiation decreased to the background level in 10 min. By contrast, on 15 MV irradiation, the dose rate was 628 nSv/h after 10 min and decreased to 268 nSv/h after 1.5 hours. It was confirmed that the difference in the level of radiation and the type of nuclide depends on the period of use, energy, and workload. However, the type of nuclide does not differ significantly between the linacs. It is necessary to propose appropriate guidelines for the safety of workers, and disposal/move-install should be planned while taking into consideration the equipment's energy usage rate.


Manganese , Radioisotopes , Humans , Radiotherapy Dosage , Particle Accelerators , Photons , Spectrum Analysis
16.
Biomed Phys Eng Express ; 10(3)2024 Apr 22.
Article En | MEDLINE | ID: mdl-38652667

Utilising Machine Learning (ML) models to predict dosimetric parameters in pencil beam scanning proton therapy presents a promising and practical approach. The study developed Artificial Neural Network (ANN) models to predict proton beam spot size and relative positional errors using 9000 proton spot data. The irradiation log files as input variables and corresponding scintillation detector measurements as the label values. The ANN models were developed to predict six variables: spot size in thex-axis,y-axis, major axis, minor axis, and relative positional errors in thex-axis andy-axis. All ANN models used a Multi-layer perception (MLP) network using one input layer, three hidden layers, and one output layer. Model performance was validated using various statistical tools. The log file recorded spot size and relative positional errors, which were compared with scintillator-measured data. The Root Mean Squared Error (RMSE) values for the x-spot and y-spot sizes were 0.356 mm and 0.362 mm, respectively. Additionally, the maximum variation for the x-spot relative positional error was 0.910 mm, while for the y-spot, it was 1.610 mm. The ANN models exhibit lower prediction errors. Specifically, the RMSE values for spot size prediction in the x, y, major, and minor axes are 0.053 mm, 0.049 mm, 0.053 mm, and 0.052 mm, respectively. Additionally, the relative spot positional error prediction model for the x and y axes yielded maximum errors of 0.160 mm and 0.170 mm, respectively. The normality of models was validated using the residual histogram and Q-Q plot. The data over fit, and bias were tested using K (k = 5) fold cross-validation, and the maximum RMSE value of the K fold cross-validation among all the six ML models was less than 0.150 mm (R-Square 0.960). All the models showed excellent prediction accuracy. Accurately predicting beam spot size and positional errors enhances efficiency in routine dosimetric checks.


Neural Networks, Computer , Proton Therapy , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Proton Therapy/methods , Radiometry/methods , Humans , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Machine Learning , Reproducibility of Results , Protons
20.
BMC Womens Health ; 24(1): 249, 2024 Apr 18.
Article En | MEDLINE | ID: mdl-38637783

BACKGROUND: Image-guided adaptive brachytherapy (IGABT) demonstrates an excellent local control rate and low toxicity while treating cervical cancer. For intracavitary/interstitial (IC/IS) brachytherapy (BT), several applicators are commercially available. Venezia (Elekta, Sweden), an advanced gynecological applicator, is designed for IC/IS BT for treating locally advanced cervical cancer. There are two types of interstitial needles for the Venezia applicator: the round needle and sharp needle. Generally, a round needle is safer because it has less risk of damaging the organ at risk than a sharp needle. However, there is currently no evidence to suggest that a round needle is better than a sharp needle for the Venezia applicator in IC/IS BT. Herein, we documented our experience of using both round and sharp needles with the Venezia applicator in IC/IS BT for cervical cancer. CASE PRESENTATION: A 71-year-old woman was diagnosed with clinical stage T2bN0M0 and the International Federation of Gynecology and Obstetrics stage IIB cervical squamous cell carcinoma. Definitive therapy, including a high-dose-rate BT boost, was planned using a round needle with the Venezia applicator in IC/IS BT. After inserting four interstitial round needles during the first and second BT sessions, an unexpectedly large gap (1.5 cm) was detected between the cervix and ovoid. We therefore used a sharp needle with the Venezia applicator for IC/IS BT during the third and fourth BT sessions. Three sharp needles were firmly inserted during the third and fourth BT sessions. CONCLUSIONS: The study findings suggest that the interstitial round needle should not be used for cervical cancer patients undergoing IC/IS BT using the Venezia applicator.


Brachytherapy , Carcinoma, Squamous Cell , Uterine Cervical Neoplasms , Female , Humans , Aged , Uterine Cervical Neoplasms/radiotherapy , Uterine Cervical Neoplasms/pathology , Cervix Uteri/pathology , Carcinoma, Squamous Cell/radiotherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
...